Vertiv Liebert GXT5 On-Line 6KVA /6kW 230V LCD PF1.0 5U Extended Run Rack/Tower, webcard and Rail Kit Bundled (GXT5-6000IRT5UXLN)

279,500.00

Description

The Liebert® GXT5™ UPS is a single phase, online double conversion UPS solution which offers premium power outage protection and continuous power conditioning in a compact and flexible deployment system. The new Liebert® GXT5™ from Vertiv™ is an advanced version of the widely-regarded GXT UPS Series. GXT5 is ideally suited to protect critical infrastructure in both centralized and edge network applications.

Best Suited For:
  • Banking, Financial and Insurance
  • Data Center/Colocation/Hosting
  • Education
  • Government
  • Healthcare
  • Manufacturing
  • Retail and Wholesale
  • Telecom
  • Transportation

Warranty: 3 Years Warranty

GET BROCHURE

             Get Manual         

Technical Information

Ratings (VA/W) 6000 VA / 6000 W

Dimensions and Weight

Dimensions (mm) Unit, W×D×H  430×630×217

Unit Weight (kg) 70.8

Input AC Parameters 

Operating Frequency, Nom 50 or 60 Hz (Factory default is 50 Hz )

Factory Default Voltage 230 VAC

Operating Voltage Range Without Battery Operation 176 to 288 VAC (100 to 176 VAC with power derating)

176 to 288 VAC (100 to 176 VAC with power derating) 288 VAC

Input Frequency Without Battery Operation 40 to 70 Hz

Output AC Parameters 

AC-AC Efficiency 94%

User-configurable Voltage  200/208/220/230/240 VAC

Factory Default Voltage 230 VAC

Factory Default Voltage 50 Hz or 60 Hz, Nominal

Waveform Pure Sinewave

Output Power Connection – Output Terminal Block

Main Mode Overload >150% minimum 200 ms, 125 – 150% for 60 seconds; 105 – 125% for 5 minutes; ≤ 105% continuous

Internal Battery

Charger Current :2.25 A (default), maximum 5 A

Type Valve-regulated, non-spillable, lead acid

Qty x V x Rating  – 2×8 x12V x 90 AH

Back-up Time at Full Load  5,5

Back-up Time at Half Load  14,5

Bypass Protection Limits

Upper-limit Selections + 10%, + 15%, + 20%; default + 10%.

Lower – limit Selections – 10% – 15% -20% default – 15%

Disable-bypass Operation When the input frequency prevents synchronous operation

General

Operating Temperature, °C Full power up to 40 oC (up to 50 oC with derating)

Storage Temperature, °C – 15 to + 40

Relative Humidity – 0 – 95% non-considering 

Operating Elevation Up to 3,000 m (9,842.5 ft) at 25°C (77°F) without derating

Audible Noise – <55 dBA

Safety UL-1788 (Fifth Edition),C-UL listed, IEC 62040-1: 2017 Edition 2.0, EN 62040-1:2008+A1:2013

EMI/EMC/C-Tick EMC =  IEC/EN/AS 62040-2 2nd Ed (Cat 2 – Table 6); FCC Part 15 (Class A) CISPR22 Class A (RFI)

ESD IEC/EN EN61000-4-2, Level 4, Criteria B

Radiated Susceptibility – IEC/EN EN61000-4-3, Level 3, Criteria A

Electrical Fast Transient- IEC/EN EN61000-4-4, Level 4, Criteria B

Surge Immunity IEC/EN EN61000-4-5, Level 4, Criteria A; ANSI C62.41 Category B

Transportation ISTA Procedure 1E

 

POD

Model Number : PD5-CE6HDWRMBS

Amp Rating 50 A

Includes

Two ICE320 C19 16 A / 250 V Sockets, Six C13 10 A / 250 V Sockets

Warranty 3 Years

Reviews

There are no reviews yet.

Be the first to review “Vertiv Liebert GXT5 On-Line 6KVA /6kW 230V LCD PF1.0 5U Extended Run Rack/Tower, webcard and Rail Kit Bundled (GXT5-6000IRT5UXLN)”

Your email address will not be published. Required fields are marked *